Asset Twin example
Polled 2026-10-12 09:13:43 · every 60.0 s

DE

Low Not assessed  Not placed on a machine yet

No open alert.

Likely faults

FaultLikelihoodSeen on
Lubrication issue 60% Horizontal
Process related loading 40% Horizontal

Each axis is analysed on its own; a fault seen on several shows the highest likelihood any of them reports, never a sum.

What changed

Low Frequency
Change in velocity for low frequency band <<7-13:Hz>> for mode 1 has been detected.
Vertical 2026-09-07 21:31
Emerging Mode
New mode 2 has been detected.
Axial 2026-09-07 21:27
Low Frequency
Change in velocity for low frequency band <<2-8:Hz>> for mode 1 has been detected.
Horizontal 2026-09-07 19:39

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now.


Axes

AxisPriorityLatest measurement
Horizontal Low 2026-09-07 23:35 Analysis and trends →
Vertical Low 2026-09-07 23:35 Analysis and trends →
Axial Low 2026-09-07 23:35 Analysis and trends →

History

No alerts yet.

Placement

Place this measuring point on a machine

There are no machines yet. Add a site and its machines under Sites & machines.

This measuring point in the API reference